Test CDCS Engine - CDCS Reliable Exam Price
Three versions of CDCS study materials will be offered by us. Eech one has it’s own advantage, you can pick the proper one for yourself. We also have free demo for you, you can have a look at and decide which version you want to choose. We also have the live chat service and the live off chat service to answer all questions you have. If you failed to pass the exam , money back will be guaranteed, if you have another exam to attend, we will replace another CDCS Study Materials for you freely.
Perhaps you still cannot believe in our EXIN CDCS study materials. You can browser our websites to see other customers real comments. Almost all customers highly praise our EXIN CDCS Exam simulation. In short, the guidance of our CDCS practice questions will amaze you. Put down all your worries and come to purchase our CDCS learning quiz!
EXIN EPI Certified Data Centre Specialist Exam Lab Questions & CDCS valid VCE test & EXIN EPI Certified Data Centre Specialist Exam Simulator Online
To practice for a EXIN EPI Certified Data Centre Specialist in the software (free test), you should perform a self-assessment. The EXIN CDCS practice test software keeps track of each previous attempt and highlights the improvements with each attempt. The EXIN CDCS Mock Exam setup can be configured to a particular style & arrive at unique questions.
EXIN CDCS Exam Syllabus Topics:
Topic
Details
Topic 1
Topic 2
Topic 3
EXIN EPI Certified Data Centre Specialist Sample Questions (Q41-Q46):
NEW QUESTION # 41
What is a potential disadvantage of using a hypoxic-based fire suppression system as a fire extinguishing system?
Answer: D
Explanation:
A hypoxic-based fire suppression system works by reducing the oxygen level in a room to below what is necessary to sustain combustion. This makes it effective in fire prevention, but it is not suitable for continuous occupancy by personnel. Low oxygen levels can cause discomfort or even health risks for people spending extended periods in the space. Therefore, these systems are typically deployed in areas where continuous human occupancy is not required, such as storage rooms or data halls with limited personnel access.
Detailed Explanation:
Hypoxic fire suppression systems lower oxygen levels to around 15-16%, which is safe for short periods but not sustainable for continuous occupancy without risk to health. Data center environments where staff need to spend long periods monitoring and maintaining equipment would need alternative systems, like gas-based suppression that allows for safe evacuation rather than oxygen reduction.
EPI Data Center Specialist References:
The EPI Data Center Specialist curriculum emphasizes that fire suppression systems must be chosen based on occupancy requirements. Hypoxic systems are specifically noted as unsuitable for spaces requiring continuous human presence due to the low oxygen environment they create.
NEW QUESTION # 42
You are allowed to use a calculator for this question. A battery bank is rated at a total capacity of 600 Ah. Calculate how much charging current the rectifier should be able to supply as charging current.
Answer: D
Explanation:
To determine the charging current for a battery bank, a general rule of thumb is that the charging current should be 5% of the total battery capacity. For a battery rated at 600 Ah, this calculation would be:
600 Ah×0.05=30 Amperes600 , ext{Ah} imes 0.05 = 30 , ext{Amperes}600Ah×0.05=30Amperes This ensures the battery is charged efficiently without overloading the rectifier or risking battery damage.
Detailed Explanation:
Battery charging current is typically set as a percentage of the battery's capacity to balance effective charging with longevity and safety. A 5% charging rate is standard for lead-acid batteries, which would be 30 Amperes for a 600 Ah battery bank.
EPI Data Center Specialist References:
EPI standards recommend calculating charging currents based on a percentage of the battery capacity to ensure safety and efficiency, aligning with best practices for battery management in data centers.
NEW QUESTION # 43
The pipes of a VESDA smoke detection system are installed at the air intake of the air conditioner inside the computer room.
Is this a good practice from an early smoke detection point of view?
Answer: B
Explanation:
For optimal early smoke detection in a data center, it is crucial that the Very Early Smoke Detection Apparatus (VESDA) system be installed at locations where smoke will be detected as soon as it appears. Positioning the VESDA pipes at the air intake of the air conditioner inside the computer room is not ideal. This placement could result in a delayed detection response and the potential for bypass airflow to occur, which would impede the system's ability to detect smoke effectively.
Detailed Explanation:
When VESDA pipes are installed at the air intake, the detection system relies on the smoke to be drawn into the air conditioning unit before detection can occur. This setup increases the reaction time as the smoke has to travel through the intake and get processed by the air conditioner. Furthermore, bypass airflow-a phenomenon where not all the air containing smoke particles passes through the VESDA pipes-could also delay or even prevent the system from detecting smoke early.
Ideally, VESDA pipes should be positioned where smoke is likely to accumulate first, such as near the ceiling or in the return airflow path to detect smoke at the earliest possible stage. This ensures that the detection system can quickly trigger alarms, providing more time to address potential fire hazards.
EPI Data Center Specialist References:
EPI Data Center Specialist training highlights that smoke detection should prioritize early response capabilities to maximize safety. The preferred installation for VESDA pipes is generally at points where smoke would naturally accumulate, rather than relying on air conditioning intakes where airflow can vary and delay detection. In their course materials, EPI emphasizes minimizing reaction time and reducing the impact of airflow dynamics on smoke detection efficiency.
NEW QUESTION # 44
What indicates the breaking capacity of a fuse or breaker?
Answer: D
Explanation:
The breaking capacity of a fuse or breaker indicates the maximum current it can safely interrupt without being damaged or creating a dangerous arc. This value is crucial for ensuring that the device can handle fault conditions and prevent equipment damage or fire risks due to excessive current flow.
Detailed Explanation:
The breaking capacity, also known as the interrupting rating, ensures that the fuse or breaker can safely handle fault currents up to a specified limit. Exceeding this capacity could result in the device failing to interrupt the current, potentially causing hazardous conditions like electrical arcs.
EPI Data Center Specialist References:
EPI training underscores the importance of matching fuses and breakers with appropriate breaking capacities for the anticipated fault levels in data centers to ensure reliable and safe operation.
NEW QUESTION # 45
Is it allowed to make design changes during the implementation phase?
Answer: B
Explanation:
Design changes during the implementation phase are generally allowed only when there is a strong business and/or technical justification. Changes at this stage can lead to delays, increased costs, or compromise design integrity. Thus, a rigorous assessment is required to ensure any modifications are essential and provide clear benefits or address critical issues.
Detailed Explanation:
Changes post-design freeze should be minimized to avoid scope creep and additional costs. However, if a technical issue arises that would affect operational goals, or a business need warrants modification, justified changes are permissible, following an impact assessment and approval process.
EPI Data Center Specialist References:
EPI project management guidelines recommend a controlled change management process during implementation, allowing changes only when they align with critical objectives or address unforeseen issues that affect the project's success.
NEW QUESTION # 46
......
The GuideTorrent is one of the reliable and trusted platforms that has been offering top-notch, real, and updated CDCS practice test questions for many years. Over this long time period, thousands of EXIN CDCS certification exam candidates have passed their CDCS certification exam. They all used valid, updated, and real EXIN EPI Certified Data Centre Specialist CDCS Exam Dumps and got ready to perform well in the final CDCS test. You can trust GuideTorrent CDCS practice test questions and start EXIN EPI Certified Data Centre Specialist CDCS test preparation without wasting further time.
CDCS Reliable Exam Price: https://www.guidetorrent.com/CDCS-pdf-free-download.html
908-460-6270
info@wavyenglish.com
971 US HIGHWAY 202N, STE N BRANCHBURG, NJ 08876